BSKQB - NICKEL CADMIUM CELLS AEROSPACE
- MSDS: BSKQB
- Manufacturer: GATES ENERGY PRODUCTS
- Product Name: NICKEL CADMIUM CELLS AEROSPACE
- National Stock Number: 6140-00N047522
Product Identification
Product ID:NICKEL CADMIUM CELLS AEROSPACE
MSDS Date:10/28/1987
FSC:6140
NIIN:00N047522
MSDS Number: BSKQB
Responsible Party
US
Emergency Phone: 904-462-3911
Info Phone: 904-462-3911
Cage: 19209
Contractor
Telephone: 904-462-3911
Cage: 19209
Ingredients
NICKEL
CAS: 7440-02-0
RTECS: QR5950000
Fraction By Weight: 20-30%
OSHA PEL 1 MG/M3
ACGIH TLV: 0.05 MG/M3
NICKEL HYDROXIDE
OSHA PEL N/K
ACGIH TLV: N/K
CADMIUM
CAS: 7440-43-9
RTECS: EU9800000
Fraction By Weight: 13-15%
OSHA PEL 0.2 MG/M3
ACGIH TLV: 0.1 MG/M3
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
POTASSIUM HYDROXIDE
CAS: 1310-58-3
RTECS: TT2100000
Fraction By Weight: 2-04%
OSHA PEL 2.0 MG/M3, C
ACGIH TLV: 2.0 MG/M3, C
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
COBALT
CAS: 7440-48-4
RTECS: GF8750000
Fraction By Weight: 1-2%
OSHA PEL 0.1 MG/M3
ACGIH TLV: 0.1 MG/M3
COBALT HYDROXIDE
CAS: 1307-86-4
RTECS: GG0904000
OSHA PEL N/K
ACGIH TLV: N/K
CADMIUM HYDROXIDE
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ELECTROLYTE IS CAUSTIC. CONTACT WITH
SKIN OR EYES MAY CAUSE IRRITATION.
Explanation of Carcinogenicity:CADMIUM: IARC MONOGRAPHS, SUPPLEMENT,
VOL 7, PG 139,. 1987: GRP 2A. NTP 6TH ANNUAL REPORT ON CARCINS,
1991: (SUPP DATA)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYE/SKIN: FLUSH W/PLENTY OF RUNNING WATER FOR AT LEAST 15 MIN
AND CONTACT A PHYSICIAN. INHAL: REMOVE TO FRESH AIR SUPPORT
BREATHING (GIVE O*2/ARTF RESP). INGEST: GET MD IMMEDIATELY .
Fire Fighting
Extinguishing Media:EXTINGUISHING MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:CADMIUM FUMES MAY BE RELEASED DURING
BURNING.
Accidental Release
Spill Release Procedures:FLUSH ELECTROLYTE SPILLS WITH WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT SHORT CIRCUIT; MAY CAUSE BURNS.
Other Precautions:AVOID INCINERATION OR MUTILATION.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLAN OF CARCIN:ANTICIPATED TO BE CARCIN. NICKEL: IARC MONOGRAPHS ON
THE EVAL OF CARCIN RISK OF CHEMS TO MAN, VOL 49 PG 257, 1990: GRP
2B. NTP 6TH ANNUAL REPORT ON CARCINS, 1991: ANTICIPATED TO BE CA
RCIN. COBALT & COBALT HYDROXIDE: IARC MONOGRAPHS ON THE EVAL OF
CARCIN RISK OF CHEMS TO MAN, VOL 52, P 363, 1991:GRP 2B.
Chemical Properties
HCC:N1
Stability
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:DO NOT INCINERATE OR MUTILATE; MAY
BURST OR RELEASE TOXIC MATERIALS.
Disposal
Waste Disposal Methods:IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.